Телефон: +7 (343) 3822503
E-mail: mir3822504@yandex.ru
1.Gas Insulated Switchgear (GIS), voltage 24kV.
15. Module block Speedbar for distribution panel
1. Gas Insulated Switchgear (GIS), voltage 24kV.
Today in electrical networks of the world we have tendency to reduction dimensions of transformer substations. We offer GIS from Company «World of electricity» to your substations.
Comparison of dimensions :
• Due to the excellent dielectric strength of SF6 Gas, the width of unit circuit which determines the installation size is reduced to 600mm resulting in downscaling of the size required for installation.
• It is assembled with standard components so it is convenient to couple and operate. It is easy to carry around on site and its installation is so simple that is reduces the installation cost.
• The charging part that forms the electric line is installed inside the ground metal which ensures the safety of operators and inspectors.
• It is a new-concept product with SF6 Gas that aims for a flawless and maintenance-free product. It is highly reliable and it does not require the maintenance work for a long period of time.
• It is a product that harmonizes with the modernized surrounding due to the user-centered external structure, low noise and minimized inductive interference.
Single or double bus types of GIS:
Single Bus System Configuration
Double Bus System Configuration
2. Gas Insulated Ring Main Unit for distribution network and substation, voltage 12, 27kV
Typical uses - Simple outdoor substation, customer transfer substations and distribution substations Industrial plants and underground stations
Comparison of dimensions :
Highly Reliability: At atmospheric gas pressure, it ensure the rated insulation and interruption capabilities.
Pure puffer techniques, no leakage current path between open contacts. Switchgear vessel made of stainless steel. Maintenance-free concept. SF6 gas insulation and interruption. Sealed pressure system. Climate-independent.
Current: 200-630(1250)A.
Mechanical endurance: 5000 manual switches.
Safety: Safe-to-touch and hermetically sealed enclosure
Overpressure relief device Pad lock
Easy installation and operation
3. Gas Insulated Ring Main Unit for distribution network and substation with fuse protection, voltage 12, 27kV
Typical uses - Simple outdoor substation, customer transfer substations and distribution substations Industrial plants and underground stations
Comparison of dimensions :
Highly Reliability: At atmospheric gas pressure, it ensure the rated insulation and interruption capabilities. Pure puffer techniques, no leakage current path between open contacts. Switchgear vessel made of stainless steel. Maintenance-free concept SF6 gas insulation and interruption. Sealed pressure system. Climate-independent.
Current: 200-630(1250)A.
Mechanical endurance: 5000 manual switches.
Safety
Operation interlock with manual shutter Safe-to-touch and hermetically sealed enclosure HV parts are only accessible when outgoing feeders are earthed Overpressure relief device Pad lock
Easy installation and operation.
The speed of close/open is independent of the speed of lever movement.
4. Gas Insulation Pole mounted switch and Automated circuit recloser, voltage 12-38kV
Typical uses - Overhead distribution line
Feature: Counter of operation times. Front and bottom On/OFF indicator. Pressure gauge
Safety: Hermetically sealed enclosure. Overpressure relief device. Manual locking device. Low gas pressure interlock device. Easy installation and operation.
Highly Reliability: At atmospheric gas pressure, it ensure the rated insulation and interruption capabilities. Pure puffer techniques, no leakage current path between open contacts. Switchgear vessel made of stainless steel. Double sealing techniques with EPDM rubber. Maintenance-free concept. SF6 gas insulation and interruption. Climate-independent. Simple operating mechanism.
Current: 630A.
Mechanical endurance: 5000 manual switches.
Ambient temperature -25 ~ 70 °C
5. Vacuum circuit breakers and Vacuum interrupters voltage 7,2-36kV
Voltage: 7,2-36kV
Current: 400-3150A
Breaking capacity: 8-40kA
Types:
6. Protection relay
Common FM & DG:
• Over-Current Relay Instantaneous & Time Delay Element, OCR(50, 51)
• Ground Over-Current Relay Instantaneous & Time Delay Element, OCGR(50G, 51G)
• Directional Over-Current Relay Instantaneous & Time Delay Element, DOCR(67)
• Directional Ground Over-Current Relay Instantaneous & Time Delay Element, DOCGR(67N)
• Selective Ground Relay Definite Time Element, SGR(67G)
• Over Voltage Relay Time Delay Element, OVR(59)
• Low Voltage Relay Time Delay Element, UVR(27)
• Over Voltage Ground Relay Time Delay Element, OVGR(64G)
• Open-Phase Relay Definite Time Element, POR(47P)
• Negative-Phase Over Voltage Relay Definite Time Element, NSOVR(47N)
• Negative-Phase Over Current Relay Definite Time Element, NSOCR(46)
• Over Frequency Relay Definite Time Element, OFR(81O)
• Under Frequency Relay Definite Time Element, UFR(81U)
• Synchronization Detection, Sync(25)
• Reclosing Relay, Auto-Reclosing(79)
• Inrush Detection, Inrush Detector
Power Quality:
• Harmonic(Voltage and Current of each Phase)
• K-Factor, Crest Factor
• Sag / Swell
Communication:
• 1 Front RS232 Port(For PC HM)
2 Rear RS422/485 Ports(For DNP3.0, MODBUS RTU)
Measurement:
• Current(Phase, Ground, Zero Phase)
• Voltage(Phase, Phase-Phase, Ground)
• Power(Active, Reactive, Apparent)
• Electric Energy(Active, Reactive, Apparent)
• Reverse Electric Energy(Active, Reactive, Apparent)
• Power-Factor(PF)
• Frequency(Hz)
• Demand(Current, Active Power, Reactive Power, Apparent Power)
I/O Channe:
• 5 for Current Input(3 for Phase, 1 for Ground, 1 for ZCT)
• 5 for Voltage Input(3 for Phase, 1 for GPT, 1 for Bus)
• 22 for Digital Input(22 for User)
• 20 for Digital Output (2 for CB ON, 2 for CB OFF & Trip, 15 for User, 1 for System Fail)
7. Vacuum equipment: Vacuum transfer switch, Vacuum contact switch
Vacuum transfer switch
Voltage: 7,2kV
Current: 400-600A
Type: Fixed, Draw-Out
Transfer sequence: A-B, A-N-B
Vacuum interrupter
Vacuum contact switch
Voltage: 3,3-6,6kV
Current: 200-400A
Type: Fixed, Draw-Out, PF mounted
Vacuum interrupter
Fuse protection
Optimal switching capacity for motor and condenser
8. Complex insulated tubular Busbar, voltage 36kV, current up to 9000A
Voltage: 0,44-35kV
Current: 1600-9000A
Breaking capacity: 125-200кА
IP: up to IP67
Distance between poles: 275-450mm
Bending radius: 350-500mm
9. Air insulation circuit breaker (ACB), voltage 0,4kV
Voltage : 0,4kV
Current : 600-4000A
Number of poles: 3,4
Protection relay: Electronic adjustable
Breaking capacity: 60-100kA
Type: Fixed, Draw-Out
10. Molded case circuit breaker (MCCB), voltage 0,4kV
Voltage: 0,4kV
Current: 1-1600A
Number of poles: 1,2,3,4
Breaking capacity: up to 85кА
11. Miniature circuit breaker (MCB), residual circuit breaker, (RCB) residual circuit breaker with overload protection (RCBO), voltage 0,4kV
Voltage: 0,4kV
Current: 1-125A
Number of poles: 1,2,3,4
Breaking type: В, С, D
Breaking capacity: 10kA
12. Auto transfer switch (ATS), voltage 0,4kV
Voltage: 0,4-0,6kV
Current: 100-3000A
Number of poles: 2,3,4
Endurance:
Mechanical — 50000
Electrical — 250000
Operation voltage: 110, 220V
13. Magnetic contactor (MC), Thermal overload relay (TOR), voltage 0,4kV
Voltage: 0,4-0,69kV
Current: 9-800А
Number of poles: 2,3
14. Copper and aluminum Busway system, voltage 0,4kV, current up to 7500A
Voltage: 1 — 24,5kV
Current : 400-7500А
BUSWAY uses very special high thermal conductivity epoxy insulation (Class F). The epoxy powder is applied by an automated fluidized bed process to ensure uniform thickness.
The uniform thickness and smooth surface provided by epoxy ensures that the insulation will have no cavities or voids and also provides excellent edge coverage to the bars.
15. Module block Speedbar for distribution panel
We offer new technology to making electrical panels with new Speedbar blocs
Old type cabinet panel Speedbar cabinet panel
620017, Russia, Ekaterinburg-city, Frontovih brigad street 31, of.209
Telephone: +7 (343) 3617955, 3617925
Website: www.mirelectro.su